The FLIR MR77 has everything you need for moisture remediation or HVAC: a pinless moisture sensor and pin probe, a temperature and relative humidity sensor, and an IR thermometer. The meter includes Bluetooth® for remote viewing and sharing, as well as METERLiNK® technology to wirelessly embed readings into radiometric infrared images on compatible FLIR thermal cameras. Made with field-replaceable sensors, the MR77 is engineered to help you get more done in less time.
FLIR MR77 5-in-1 Moisture Meter with METERLiNK®
ALL THE SENSORS YOU NEED
All-in-one tool featuring an integrated pinless moisture sensor, a pin-type probe, a temperature and relative humidity sensor, and an IR thermometer
BUILT TO LAST
The double-molded, rubberized case is shock-resistant from drops as high as two meters to bolster reliability and durability.
CREATE REPORTS FAST
Wirelessly connect to a compatible mobile device to share data and integrate readings onto images from FLIR thermal cameras.
| Highlighted | |
| IR Temperature | Range -4 to 392°F, -20 to 200°C / Basic Accuracy +/- 3.5% |
| Pin Moisture | Range 0 to 99% WME / Basic Accuracy +/- 5% |
| Pinless Moisture | Range 0 to 99.9 / Basic Accuracy Relative |
| Sensor Temperature | Range -18 to 170°F, -28 to 77°C / Basic Accuracy +/- 3.6°F, 2°C |
| Relative Humidity | Range 0 to 99% RH / Basic Accuracy +/- 2.5% RH |
| Imaging & Optical | |
| Gallery | 17561 |
| Sensor Temperature | Range -18 to 170°F, -28 to 77°C / Basic Accuracy +/- 3.6°F, 2°C |
| Measurement & Analysis | |
| IR Distance to Spot Ratio | 8 : 1 in |
| IR Emissivity | Range 0.95 (fixed) |
| IR Temperature | Range -4 to 392°F, -20 to 200°C / Basic Accuracy +/- 3.5% |
| Pin Moisture | Range 0 to 99% WME / Basic Accuracy +/- 5% |
| Pinless Moisture | Range 0 to 99.9 / Basic Accuracy Relative |
| Pinless Moisture Depth Max | 0.75 inches (19mm) |
| Communication & Data Storage | |
| Bluetooth range max | 32 ft (10 m) |
| General | |
| Packaging Size | 13.5 cm x 11 cm x 30 cm (5.3? x 4.8? x 11.8?) |
| Environmental & Certifications | |
| Certifications | CE, FCC |
| Drop test | 6.5 ft (2 m) |
| Relative Humidity | Range 0 to 99% RH / Basic Accuracy +/- 2.5% RH |
| Vapor Pressure | Range 0 to 20.0kPA / Basic Accuracy +/- 2% |
| Warranty | Limited Lifetime |
Export Restrictions
The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.