The FLIR Si2a-Pro combines partial discharge detection and leak detection in one fixed acoustic imaging camera. It helps teams identify PD activity, corona, arcing, compressed air leaks and industrial gas leaks earlier — supporting safer diagnostics, reduced downtime and improved plant reliability.
DETECT ELECTRICAL FAULTS AND LEAKS BEFORE THEY BECOME COSTLY
Continuous fixed acoustic monitoring for partial discharge, compressed air leaks and pressurised gas leaks.
DUAL ACOUSTIC MONITORING
Built for electrical faults and leak-related losses.
The FLIR Si2a-Pro supports continuous monitoring across electrical and industrial assets — helping teams detect partial discharge activity, compressed air leaks and pressurised gas leaks before they become downtime, safety risks or unnecessary operating costs.
PD Monitoring
Leak Detection
Gas Systems
Switchgear & GIS
Compressed Air
Assetlink
WHY IT MATTERS
Smarter monitoring. Safer decisions. Lower losses.
Continuous acoustic monitoring helps maintenance teams detect risk earlier, reduce manual inspection pressure and respond with confidence across both electrical and leak detection applications.
One Camera. Two Critical Risks.
Find Faults and Losses Earlier
AI Turns Signals Into Action
AI-driven analysis helps classify faults, assess severity, estimate leak impact and support faster decisions.
KEY CAPABILITIES
Engineered for continuous acoustic monitoring.
The FLIR Si2a-Pro is designed for fixed, always-on monitoring in demanding electrical and industrial environments. With long-range acoustic detection, rugged IP66 protection, flexible connectivity, AI-assisted severity assessment and leak cost estimation, it helps teams monitor critical assets continuously and respond before problems become costly failures.
124 MEMS microphones
Low-noise acoustic array with real-time sound visualisation.
Up to 200 m detection
Long-range monitoring for safer diagnostics.
PD + leak detection
Detect partial discharge and pressurised gas leaks.
Leak cost estimation
Estimate leak size and annual cost impact.
IP66 rated
Built for harsh industrial and utility environments.
Assetlink compatible
Centralised monitoring and asset management workflows.
MONITORING ADVANTAGES
Detect, quantify, alert and integrate.
From PD severity assessment to leak size and cost estimation, the Si2a-Pro helps teams move from scheduled manual inspections to continuous, event-driven acoustic monitoring.
Continuous 24/7 monitoring of partial discharge and pressurised gas leaks
Detects PD, corona, arcing, compressed air leaks and industrial gas leaks
Automatic leak recognition with estimated leak size and annual cost
PD type recognition and AI-based severity assessment
IP66-rated fixed installation for harsh industrial and utility environments
Compatible with FLIR Assetlink and enterprise workflows
MONITORING ADVANTAGES
Built for fixed installation in demanding environments.
From configurable monitoring zones to FLIR Assetlink integration, the Si2a-PD gives teams the tools to monitor electrical assets continuously, receive alerts when thresholds are exceeded and act on clear severity-based insights.
| Highlighted | |
| Acoustic Measurement | 124 low-noise MEMS microphones, real-time sound visualisation |
| Operating Distance | From 0.3 m / 1.0 ft up to 200 m / 656 ft |
| Leak Localisation & Detection | Automatic leak recognition including estimated leak size and annual cost |
| Severity Assessment | Automatic AI-based severity assessment including recommended actions |
| Ingress Protection | IP66 |
| Acoustic & Analysis | |
| Bandwidth | 2–130 kHz |
| Directional Resolution | From 1° up to 0.125° |
| Leak Rate Detection Threshold | 0.0032 l/min from 2.5 m; 0.0044 l/min from 6 m |
| Gases Detected | Compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas and nitrogen |
| PD Type Recognition | Surface or internal discharge, positive and negative corona, negative corona and floating discharge |
| PRPD Pattern Recognition | Automatic |
| Imaging, Connectivity & Power | |
| Digital Camera | 12 MP colour |
| Field of View | 75° diagonal |
| Video Frame Rate | Streaming: 15 fps; Snapshots: 30 fps |
| Video Image Resolution | 960 × 540 streaming, 16:9 aspect ratio |
| Network Interfaces | M12 x-code 8-pin Ethernet, PoE IEEE 802.3at |
| Wireless Connectivity | Wi-Fi 2.4 GHz / 5 GHz, IEEE 802.11 b/g/n/ac |
| Supported Protocols | TCP/IP, RTSP, MQTT, SMTP, FTP |
| Power | PoE+ Type 2, 30 W |
DETECT ELECTRICAL FAULTS AND LEAKS BEFORE THEY BECOME COSTLY
Partial discharge, corona, arcing and pressurised gas leaks can be intermittent and difficult to capture during scheduled inspections. The FLIR Si2a-Pro provides continuous acoustic monitoring so developing electrical faults and leak-related losses can be detected, assessed and prioritised earlier.
By combining electrical fault detection and leak detection in one fixed acoustic solution, the Si2a-Pro helps teams reduce risk, improve safety and identify costly losses before they escalate.
RELATED DOCUMENTS
From configurable monitoring zones to FLIR Assetlink integration, the Si2a-PD gives teams the tools to monitor electrical assets continuously, receive alerts when thresholds are exceeded and act on clear severity-based insights.
Get in Touch
Please complete the form below to submit your request.