{"product_id":"flir-ev86-t2-ev-charger-analyzer","title":"FLIR EV86-T2 EV Charger Analyzer with MeterLink","description":"\u003cp\u003e\u003cspan style=\"font-size: 18px;\"\u003eThe FLIR EV86-T2 EV Charger Analyzer with MeterLink is a portable test instrument for EV charging station operators, service and maintenance providers, electrical professionals and automotive manufacturers. It brings the principal checks needed to assess the safety and performance of residential and commercial AC charging stations into one unit, helping technicians investigate protective-earth conditions, charging-interface behaviour, RCD\/CCID operation and loop impedance. MeterLink connectivity also supports wireless capture of test results into reporting software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; margin: 18px 0 8px;\"\u003e\n\u003ca href=\"#quote-form\" style=\"display:inline-block; background:#103f73; color:#ffffff; font-size:18px; font-weight:700; text-decoration:none; padding:14px 26px; border-radius:4px; letter-spacing:0.02em;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose the FLIR EV86-T2?\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003ch3\u003eRUN THE PRINCIPAL AC CHARGER CHECKS FROM ONE INSTRUMENT\u003c\/h3\u003e\n    \u003cp\u003eAuto testing covers PE Pre-Test, the EVSE interface, RCD testing and loop impedance from the settings menu. This gives maintenance teams a practical sequence for assessing an AC charging point before deciding whether it can remain in service or needs further investigation.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eCHECK PROTECTIVE-EARTH CONDITIONS BEFORE TESTING\u003c\/h3\u003e\n    \u003cp\u003eThe PE Pre-Test measures up to 50 V AC\/DC and indicates pass or fault when more than 50 V AC\/DC is detected between the PE conductor and touch sensor. That early check helps the technician identify a potentially hazardous protective-earth condition before proceeding with the rest of the assessment.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eSIMULATE VEHICLE CONNECTION AND CONTROL-PILOT STATES\u003c\/h3\u003e\n    \u003cp\u003ePP state simulation provides Not connected, Connected and Connected + Latch conditions, while CP Error (E state) simulation provides Pass\/Fault. These functions let an operator check how an EVSE responds as connection states change and when a control-pilot error is presented.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eASSESS SINGLE-PHASE AND THREE-PHASE AC EVSE OUTPUTS\u003c\/h3\u003e\n    \u003cp\u003eThe EVSE interface supports single-phase operation to 250 V maximum and three-phase operation to 230 \/ 440 V maximum at 50 \/ 60 Hz and a maximum of 10 A. Voltage phase indication for L1, L2, L3, PE and N helps the technician identify the conductors present during testing.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eTEST RCD AND CCID TRIPPING BEHAVIOUR\u003c\/h3\u003e\n    \u003cp\u003eThe EV86-T2 provides trip-time and ramping-current tests for the AC and DC protection conditions listed in its specification. Testing at 0° and 180° gives service teams defined results for diagnosing protective-device operation at an AC charging station.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eWORK ACROSS TYPE 2 AND TYPE 1 CONNECTIONS\u003c\/h3\u003e\n    \u003cp\u003eA Type 2 connection is built into the analyzer, and a Type 2-to-Type 1 converter is included. This allows one test kit to support the two connector types without requiring a separate analyzer.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003ch3\u003eCAPTURE RESULTS WIRELESSLY FOR REPORTING\u003c\/h3\u003e\n    \u003cp\u003eBluetooth BLE connectivity provides a specified range of 10 m (32 ft), enabling MeterLink transfer of results into reporting software. A 3.5 in. TFT-LCD, rechargeable Li-Battery and 12 hours of continuous battery life support field use across multiple charging points.\u003c\/p\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKEY SPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003eDISPLAY, CONNECTIVITY AND SAFETY\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e3.5 in. TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eBluetooth BLE with 10 m (32 ft) range\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety Category\u003c\/th\u003e\n\u003ctd\u003eCAT II-300 V, IEC61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e3.5 in. TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003eEV CHARGER TESTING\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAuto Testing Items\u003c\/th\u003e\n\u003ctd\u003ePE Pre-Test, EVSE Interface, RCD Test, and Loop Impedance in Settings Menu\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCategory Rating\u003c\/th\u003e\n\u003ctd\u003eCAT II-300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCP Error (E state) Simulation\u003c\/th\u003e\n\u003ctd\u003ePass\/Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eEVSE interface\u003c\/th\u003e\n\u003ctd\u003e1 Φ: 250 V max, 3 Φ: 230 \/ 440 V max, 50 \/ 60 Hz, max 10 A Main Voltage: Range 440 V \/ Accuracy: +\/- 2.0% Frequency Range: 2 kHz \/ Accuracy: +\/- 1 Hz Duty Cycle Range:100% \/ Accuracy: +\/- 5 Digits\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLoop Impedance\u003c\/th\u003e\n\u003ctd\u003eRange: 2.000 kΩ \/ Accuracy ±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003ePE Pre-Test\u003c\/th\u003e\n\u003ctd\u003eRange: 50 V AC\/DC \/ Accuracy ±2.0%, Pass \/ Fault (\u0026gt;50 V AC\/DC Between PE Conductor and Touch Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003ePP State Simulation\u003c\/th\u003e\n\u003ctd\u003eNot connected, Connected, Connected + Latch\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eRCD\/CCID Trip Test\u003c\/th\u003e\n\u003ctd\u003eRCD Trip Time (0°, 180°) Range: 31.5 mA AC, 300 ms \/ Accuracy ±2.0% Range: 6 mA DC, 12.5s for RCD Ramping Current (0°, 180°) Range: 6 mA DC in 2.5s Smooth Ramp Every 2 mA DC, 30 mA AC in 2mA Steps Every 300 ms in .5s \/ Accuracy ±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage Phase Indication\u003c\/th\u003e\n\u003ctd\u003eL1, L2, L3, PE, N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eBluetooth BLE with 10 m (32 ft) range\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector Types\u003c\/th\u003e\n\u003ctd\u003eType 2 (Built-in), Type 1 (converter included)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003ePOWER, CONTROLS AND SUPPLIED ITEMS\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAuto Power Off\u003c\/th\u003e\n\u003ctd\u003eOff \/ 5 min \/ 10 min \/ 20 min \/ 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eRechargeable Li-Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery life\u003c\/th\u003e\n\u003ctd\u003e12 Hours Continuously\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eBox Contents\u003c\/th\u003e\n\u003ctd\u003e1 × EV86-T2 EV Charger Analyzer 1 × Converter (Type 2 to Type 1) 1 × USB Cable Type A to C 1 × Flir Quick Start Guide 1 × Neck Strap 1 × Carrying Pouch with Shoulder Strap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSize (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e296 × 94 × 50 mm (11.6 × 3.7 × 2 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e760 g (1.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003eCERTIFICATIONS AND ENVIRONMENTAL CONDITIONS\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eETL, CE, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Altitude\u003c\/th\u003e\n\u003ctd\u003e2000 m (6560 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Ambient Temperature and Relative Humidity (RH)\u003c\/th\u003e\n\u003ctd\u003e-10°C to 30°C (14°F to 86°F), \u0026lt;85% RH 30°C to 40°C (86°F to 104°F), \u0026lt;75% RH 40°C to 50°C (104°F to 122°F), \u0026lt;45% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003ePollution Degree\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety Category\u003c\/th\u003e\n\u003ctd\u003eCAT II-300 V, IEC61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature and relative humidity [RH]\u003c\/th\u003e\n\u003ctd\u003e-20°C to 60°C (-4°F to 140°F), 0 to 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eLimited 3-Year Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eDocuments and downloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1248\/0715\/files\/ev86-t2__quick-start-guide-gothermal.pdf?v=1790763802\" target=\"_blank\" rel=\"noopener\"\u003eFLIR EV86-T2 Quick Start Guide (PDF, 482 KB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat can the FLIR EV86-T2 test on an AC EV charging station?\u003c\/h3\u003e\n\u003cp\u003eThe FLIR EV86-T2 combines PE Pre-Test, EVSE interface, RCD testing and loop-impedance functions. It also provides PP state simulation, CP Error (E state) simulation and voltage phase indication for L1, L2, L3, PE and N, giving technicians a defined set of checks for investigating AC charging-station safety and performance.\u003c\/p\u003e\n\u003ch3\u003eDoes the FLIR EV86-T2 work with Type 1 and Type 2 charging connectors?\u003c\/h3\u003e\n\u003cp\u003eThe FLIR EV86-T2 has a built-in Type 2 connector and is supplied with a Type 2-to-Type 1 converter. The included converter allows the same analyzer to be used with Type 1 connections.\u003c\/p\u003e\n\u003ch3\u003eHow does MeterLink support EV charger reporting?\u003c\/h3\u003e\n\u003cp\u003eThe FLIR EV86-T2 uses Bluetooth BLE with a specified range of 10 m (32 ft). MeterLink provides wireless capture of the analyzer's results into reporting software, reducing the need to transcribe readings manually.\u003c\/p\u003e\n\u003ch3\u003eCan the FLIR EV86-T2 test single-phase and three-phase charging stations?\u003c\/h3\u003e\n\u003cp\u003eThe FLIR EV86-T2 EVSE interface supports single-phase operation to 250 V maximum and three-phase operation to 230 \/ 440 V maximum, at 50 \/ 60 Hz and a maximum of 10 A. It is intended for testing the safety and performance of AC EV charging stations in residential and commercial environments.\u003c\/p\u003e\n\u003ch3\u003eWhat should I provide when requesting a quotation?\u003c\/h3\u003e\n\u003cp\u003eFor a FLIR EV86-T2 quotation, tell GoThermal how many analyzers you need, the Type 1 or Type 2 charging connections you service, whether your sites are single-phase or three-phase, and your required delivery location in South Africa. We can then specify the appropriate supply package and provide local product support.\u003c\/p\u003e\n\u003chr\u003e\n\u003cdiv id=\"quote-form\"\u003e\u003c\/div\u003e\n\u003ch2 style=\"text-align: center;\"\u003eGet a Quote\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 18px;\"\u003eSend us your required quantity, the connector types and supply phases you test, and your South African delivery location so we can specify and quote the right FLIR EV86-T2 package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/shell.js\"\u003e\u003c\/script\u003e\n\u003cscript\u003ehbspt.forms.create({region:\"na1\",portalId:\"9311151\",formId:\"aa9dfe43-a432-4892-8135-1aab54fba146\"});\u003c\/script\u003e\n","brand":"FLIR","offers":[{"title":"FLIR EV86-T2 EV Charger Analyzer","offer_id":67597583777835,"sku":"EV86-T2","price":0.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1248\/0715\/files\/ev86-t2__ev86-t2-front-_left_45-640.webp?v=1790775657","url":"https:\/\/www.gothermal.co.za\/products\/flir-ev86-t2-ev-charger-analyzer","provider":"GoThermal","version":"1.0","type":"link"}